| INDUCTIVE LOADS CONTINUOUSLY VARIABLE 
        Nucon Single & Three Phase Inductive Loads 
        are very useful for Electrical Engineering Labs. Electrical Test Houses 
        and Industries.
 MAIN FEATURES
 
 The Coils are wound on Fiber Bobbins with best quality Super Enamled 
        Copper Wire. The Core is hot rolled steel, Sillicon Coated having low 
        hysterisis & low eddy current losses. One core is tightly fixed into the 
        lower side of the Coil and the second core slides in the remaining 
        portion of the coil through the bobbin, making close Magnetic circuit. 
        The core sliding system is provided with a Fine Threaded Steel Rod, 
        moving in a Gun Metal Block to give very fine regulations. The block is 
        fitted to the sliding core and a Hand Wheel is fitted to the rod (Lead 
        Screw) to move the core up and down inside the Magnetic Coil to give 
        very fine variation of Current. The unit works on AIR GAP PRINCIPAL. 
        With increase of the air gap the current decreases. The cores are 
        tightly bound to reduce the resonance when core slides inside the the 
        Magnetic Coil & current is maximum.
 
 This whole is fitted in a metal box, provided with four Castor Wheels to 
        make it a trolly. Finished in Duco Paint the box is provided with 
        bakelite Panel, fitted with non-flying type insulated brass terminals.
 
 NUCON INDUCTIVE LOAD single phase 50 
        Hz. 220/230 Volts. specifications as mentioned above. Two Terminals are 
        provided on the panel Continuously variable.
 Lagging Power Factor : 0.2.
 
 Max. Current 4 Amp. 5 Amp. 8 Amp. 10 Amp. 15 Amp. 20 Amp.
 INDUCTIVE LOADS : THREE PHASE 50 Hz. Three limb Core type, 
        400/415V.
 Line Voltage 230/240 Volts. Specifications as described above.
 
 Six Non Flying Type Insulated Brass Bakelite Moduled Terminals are 
        fitted on the panel to use
 the unit as explained below :
 
 i) In Star for 400/415 V. 3 Phase line System.
 ii) The Delta for 230/240V. 3 Phase Line System.
 iii) The three Inductive Coils can be connected in series.
 
 The Terminals are marked and complete operating instructions are 
        engraved on the panel.The Inductive Load are manufactured in the 
        following ranges.
 
 Max. Current/Phase 5 Amp. 8 Amp. 10 Amp. 15 Amp. 20 Amp. 25 Amp
 Three & Single Phase Inductive Loads 
        can be supplied with Meters to read Voltage & Current at the following 
        extra prices.
 
 |