GENERAL INSTRUMENTS

Cat No. Description
745

Measurement of Peak, Average & RMS Value of a AC Signal

Features : Sine Wave Output on terminals, Step Down Transformer, Circuit Diagram for peak & Average Value measurement engraved and terminals provided for inputs and outputs.
Accessories : VTVM

 
746 Verification of KCL and KVL

Features : 1 DC Regulated short circuit & Over load protected continuously variable power supplies, two round meters, combination of resistances mounted on front panel.
Accessories : Set of 2 interconnect able and 5 single point Patch Cords.

 
747 Resistances in Series & Parallel Apparatus

Objectives : To verify properties of resistances when connected in series &
parallel.
Features : Two moving coil meters to measure voltage & current, Circuits diagram for

Features : Instrument comprises of Two moving coil meters to measure voltage & current, Circuit diagram for series & parallel connections Printed & Resistances mounted on the front panel.
Optional Acc. : 6 VDC Battery

 
748 Ohm's law Apparatus

Objective : To Verify Ohm's law i.e. V = IR
Features : Instrument comprises of Two moving coil meters to measure voltage & current, One wire wound Potentiometer, Circuit diagram Printed & Connections brought out at terminals for connecting 6 Volts battery & One wire wound Resistance.
Optional Acc.: 6 VDC Battery

 
751 Charging & Discharging of condensor

Objective : To study RC time constant using various sets of Resistance & Capacitors.
Features : Instrument comprises of DC Power Supply with selector switch to select different voltages, One Centre Zero Microammeter, Circuit diagram is Printed, Terminals are provided for connecting different values of Resistances Capacitors.
Standard Acc.: Three sets of Resistances Capacitors.

 
753 Flashing & Quenching of Neon Apparatus

Objective : To calculate charge & Discharge time of a Condensor.
Features : Instrument comprises of High voltage DC Power Supply 250 VDC/30 mA, 3 Capacitors(Paper Type) connected behind the front panel, can be selected using toggle switches & One Neon lamp.

 
754 BH Curve Appts

Objective : To trace Hystersis curves on CRO using Resistance, Capacitance & Inductance.
Features : Instrument comprises of AC Power Supply 3-15 VAC, Output selectable using band switch, Circuit diagram for BH curve Printed, Components connected behind the front panel, provision for connecting external inductance, Input & Outputs Connections brought out at Sockets.
Accessories : Dual trace CRO.


 

<< BACK << >> NEXT >>