Cat
No. |
Description |
745 |
Measurement of Peak,
Average & RMS Value of a AC Signal
Features : Sine
Wave Output on terminals, Step Down Transformer, Circuit Diagram for
peak & Average Value measurement engraved and terminals provided for
inputs and outputs.
Accessories : VTVM |
|
746 |
Verification of KCL and KVL
Features : 1 DC Regulated short
circuit & Over load protected continuously variable power supplies, two
round meters, combination of resistances mounted on front panel.
Accessories : Set of 2 interconnect able and 5 single point Patch
Cords. |
|
747 |
Resistances in Series & Parallel
Apparatus Objectives :
To verify properties of resistances when connected in series &
parallel.
Features : Two moving coil meters to measure voltage & current,
Circuits diagram for
Features : Instrument comprises of Two moving coil meters to
measure voltage & current, Circuit diagram for series & parallel
connections Printed & Resistances mounted on the front panel.
Optional Acc. : 6 VDC Battery |
|
748 |
Ohm's law Apparatus
Objective : To Verify Ohm's law
i.e. V = IR
Features : Instrument comprises of Two moving coil meters to
measure voltage & current, One wire wound Potentiometer, Circuit diagram
Printed & Connections brought out at terminals for connecting 6 Volts
battery & One wire wound Resistance.
Optional Acc.: 6 VDC Battery |
|
751 |
Charging & Discharging of condensor
Objective : To study RC time
constant using various sets of Resistance & Capacitors.
Features : Instrument comprises of DC Power Supply with selector
switch to select different voltages, One Centre Zero Microammeter,
Circuit diagram is Printed, Terminals are provided for connecting
different values of Resistances Capacitors.
Standard Acc.: Three sets of Resistances Capacitors. |
|
753 |
Flashing & Quenching of Neon Apparatus
Objective : To calculate charge &
Discharge time of a Condensor.
Features : Instrument comprises of High voltage DC Power Supply
250 VDC/30 mA, 3 Capacitors(Paper Type) connected behind the front
panel, can be selected using toggle switches & One Neon lamp. |
|
754 |
BH Curve Appts
Objective : To trace Hystersis
curves on CRO using Resistance, Capacitance & Inductance.
Features : Instrument comprises of AC Power Supply 3-15 VAC,
Output selectable using band switch, Circuit diagram for BH curve
Printed, Components connected behind the front panel, provision for
connecting external inductance, Input & Outputs Connections brought out
at Sockets.
Accessories : Dual trace CRO. |