| Cat 
        No. | Description | 
      
        | 755 | Convertion of Galvanometer Into a 
        Voltmeter Features : 
        Instrument comprises of DC Regulated Power Supply 0-5 VDC/150mA, two 
        round meters One Voltmeter One Galvanometer, Three set of Resistances 
        mounted behind the panel, connections of Supplies, Meters Resistances 
        brought out at 4mm Sockets.  | 
      
        |  | 
      
        | 756 | Convertion of Galvanometer Into a 
        Currentmeter Features 
        : Instrument comprises of DC Regulated Power Supply 0-5 VDC/150mA, two 
        round meters One Milliammeter One Galvanometer, Three set of Shunts 
        mounted behind the panel, connections of Supplies, Meters Shunts brought 
        out at 4mm Sockets. | 
      
        |  | 
      
        | 757 | Voltage Doubler & Tripler Circuit 
        Objective : To Study Voltage 
        multiplication using Diodes, Resistances & Capacitors.
 Features : Instrument comprises of AC Power Supply with Output 
        selectable using band switch, Circuit diagram of Doubler and Tripler 
        Printed & Components mounted on the front panel.
 Accessories : Analog Multimeter & a set of 4 single point patch 
        cords.
 | 
      
        |  | 
      
        | 758 | Voltage Doubler Tripler Circuit with 
        two deluxe meters 
        Objective : To Study Voltage multiplication using Diodes, 
        Resistances Capacitors. Voltage Multiplication using Half wave Full wave 
        rectifiers compare the output at various loads.Features : Instrument comprises of AC Power Supply with Output 
        selectable using band switch, 3 Round meters, Load resistances can be 
        selected using band switch, Circuit diagram for Doubler and Tripler 
        Printed connections of Power Supply, Meter Components brought out at 4mm 
        Sockets
 | 
      
        |  | 
      
        | 759 | LCR Resonance Apparatus 
        Objective : To plot Frequency Vs. 
        Current Characteristics of LCR circuit when connected in series or in 
        parallel. Features : Instrument comprises of 3 Resistances, 3 Capacitors & 
        1 Inductance connected inside & connections brought out at Sockets. 2 AC 
        moving coil meters to measure voltage & current.
 Optional Acc. : Audio Frequency Function Generator .
 | 
      
        |  | 
      
        | 761 | LCR  Impedance Circuit Apparatus 
        Objective : To calculate AC power 
        factor of LCR circuit when connected in series & subjected to AC 
        voltage.Features : Instrument comprises of AC Power Supply 3-15 VAC, 
        voltage selectable using bandswitch, 2 AC moving coil meters to measure 
        voltage & current, 3 Resistances, 3 Capacitors & 1 inductance connected 
        inside & connections brought out at Sockets/Terminals.
 | 
      
        |  | 
      
        | 762 | RC Circuit (Transient Response) 
        Objective : To Study & plot graphs 
        for RC circuit as Low Pass & High Pass Filters.Features : Circuit diagram for Low Pass and High Pass Filter 
        Printed, Three Resistances, Three capacitors are placed inside and 
        connections brought out at 4mm Sockets.
 Accessories : Audio Frequency Function Generator & CRO.
 |