| Cat 
        No. | Description | 
      
        | 332 | Reversing Switch (With Lock type 
        terminals) | 
      
        |  | 
      
        | 333 | Plug-Type (One way), Brass (9/16" 
        Square rod) | 
      
        |  | 
      
        | 334 | Plug Type (Two way), Brass (9/16" 
        Square rod) | 
      
        |  | 
      
        | 335 | Tapping key (Single contact) | 
      
        |  | 
      
        | 336 | Tapping key (Double contact) | 
      
        |  | 
      
        |  | 1.0 Kelvin Double Bridge (Model No. 
        KDB-2021) Range 0.2 ohm to 11 ohm
 It is used as standard testing instrument used for accurate measurement 
        of very low resistances such as shunts, copper & aluminum 
        conductors/wire and specific resistance determinations of heavy 
        distribution transformers. The bridge comprise 10 steps of standard 
        resistance of X 0.01 ohms and a circular slide wire having total 
        resistance of 0.01 ohm & divided into 500 equal parts so that each 
        division correspond to 0.00002 ohm (or 20 micro-ohm). It is also 
        provided with 5 multiplier ranges of X 0.001, X 0.1, X 1, X 10 & 100 so 
        that the overall range becomes 0.2 Micro-ohm to 11 ohms. Provided with 
        built in compensation arrangement for taking into consideration self 
        resistance of leads from bridge to test object. Complete with one 
        standardized set of 8 leads for interconnections. All standard 
        resistance coils used inside are of Aged Manganin wire/strip so that 
        overall accuracy of 0.05 % is achieved. This model is mostly used in 
        wire & cable industries & conforms to IS : 694 & 1554 & hence it is also 
        named as Industrial Kelvin Double Bridge.
 | 
      
        |  | 
      
        |  | Accessories 
 a) DC source of 10 Amps (Model DC-341)
 
 b) Spot Reflecting Galvanometer (Model RG-321)
 
 c) Conductivity attachment of 50 cm length for holding sample (Model No. 
        CA - 361)
 
 d) Brass Clamp with very thick terminals at both side & one at centre 
        for testing zero of kelvin bridge (Model No.BC-381)
 
 e) Standard Resistance box having five values of 0.001, 0.01, 0.1, 1, 10 
        ohms enclosed in one box, used as Standard for checking Kelvin Bridge 
        (Model No. SR-391), Accuracy 0.5 %.
 | 
      
        |  | 
      
        |  | Other Models : 
 1. Senior Kelvin Double Bridge ( Model No. KDB-2041)
 ( Range 0.02 micro-ohm to 1.1 ohm)
 
 2. Precision Kelvin Double Bridge (Model No. KDB-2061),
 Range 2 micro ohm to 110 ohm)
 
 3. Wide Range Kelvin Double Bridge ( Model KDB-2081 )
 Range 20 micro-ohm to 1100 ohm)
 | 
      
        |  | 
      
        |  | Callendar and Griffth Bridge 
 Suitable for measurement of change of resistance thermometer, Coil are 
        of Manganin. The bridge wire is accurately calibrated, A vernier is 
        attached fine slow motion is available. Special mercury contacts,Length 
        of slide wire 30 cms. Resistance Values are 0.1, 0.2, 0.4, 0.8, 1.6, 
        3.2, 6.4, 12.8 ohms and 0.15 ohms for slide wire. Measurable resistance 
        0.0005 to 25.65 ohms. Accuracy of adjustment 0.01 % ( Also known as 
        Platinum Resistance Thermometer Bridge)
 | 
      
        |  | 
      
        |  | Rayleigh’s Bridge 
 For measurement of self inductance of a coil.
 
 a) Ratio arms in 3 dials of 1, 10, 100 ohms each.
 
 b) Three Rheostat dials having fractions units and tens.
 
 c) Slide wire having 0.15 ohms is connected in series with Rheostat arm.
 The slide wire is calibrated in 100 equal parts.
 
 d) Rayleigh’s special key is fitted on panel.
 
 e) Terminals for extra series and unknown inductance provided.
 | 
      
        |  | 
      
        |  | DC Potentiometer 
 It has got eight steps of 2 ohms and a slide wire of equal resistance. 
        The circular slide wire is divided into 200 parts and is calibrated to 
        read in millivolts. All these in series with coarse and fine rheostat 
        provide the standardising unit. Terminals are provided for a 2-3 volts 
        battery, standard cell, galvo and two sets of external test circuits 
        worked by a rotary switch. A self check is provided by a fixed tap in 
        the circuit corresponding to the standard cell e.m.f. of 1.0186 volts. 
        Range 0.0005 to 1.8 volts Manganin Coils. Accuracy 0.05%.
 
 a) Volt Ratio Box
 
 For extension of range of potentiometer. Range 1.5, 15, 150.300 & 750 
        volts.
 Total Resistance 37500 ohms (dial type).
 
 b) (i) Standard Cell (Cadmium) Voltage = 1.0186 V
 
 (ii) Standard Cell (Electronic)
 
 c) 2 V Accumulator (Constant Voltage Source)
 | 
      
        |  |